USULAN WAKTU PERAWATAN DAN PERBAIKAN BERDASARKAN KEANDALAN PADA BAGIAN BOILER DI PEMBANGKIT LISTRIK TENAGA UAP

Iing Pamungkas, Heri Tri Irawan, Arhami Arhami, Muhammad Dirhamsyah

Abstract


PT. PLN (Persero) is the sole manager of the electricity industry in Indonesia which is owned by the Indonesian government in the form of a State-Owned Enterprise. Steam power plant is one of the leading power plants in Indonesia. Aceh Province has one steam power plant located in Nagan Raya Regency and has two generating units with an installed capacity of 2x110 Megawatts. However, a power outage is unavoidable and still often occurs if one of the plants is damaged or damaged. Corrective maintenance activities and overall maintenance is one of the causes of the high frequency of interference or damage, especially in the boiler section. This study aims to determine the proposed maintenance and repair time to achieve a reliability level of up to 80% in every important boiler component. The proposed maintenance and repair time can be obtained based on historical time to failure and time to repair data. Good maintenance and repair time can be assessed based on high reliability values. The results obtained that the proposed maintenance time is 67 hours to 585 hours to achieve 80% reliability value on eight important components in the boiler section. While the proposed repair time is from 1,036 hours to 1,497 hours to reach 80% reliability value on eight important components in the boiler section.


Keywords


Boiler; Reliability; Maintenance; Repair

Full Text:

PDF

References


Putri E. L., Bahauddin, A., Ferdinant, P. F., 2013, Usulan Jadwal Perawatan pada Mesin Electric Arc Furnace 5 dengan Simulasi Monte Carlo, Jurnal Teknik Industri, vol 1, no 4, hal 352-257.

Pamungkas, I., Arhami., Dirhamsyah, M., 2019, Monte Carlo simulation for predicting the reliability of a boiler in the Nagan Raya steam power plant. IOP Conference Series: Materials Science and Engineering, vol 523, No 1, hal 012071.

Soesetyo, I., Bendatu, L. Y., 2014, Penjadwalan Predictive Maintenance dan Biaya Perawatan Mesin Pellet di PT Charoen Pokphand Indonesia-Sepanjang, Jurnal Tirta, vol 2, no 2, hal 147-154.

S. H. Eko, S. H., dan B. Untung, B., 2008, Analisa Keandalan Sistem Bahan Bakar Motor Induk Pada Kapal Motor Leuser, Jurnal Kapal, vol 5, no 4, hal 123-135.

Ebeling, E. C., 1997, An Introduction To Reliability And Maintainability Engineering, International Ed. Singapore: McGraw Hill, 1997.

Pamungkas, I., 2019, Penentuan Tingkat Risiko dan Keandalan pada Boiler di Industri Pembangkit Listrik Nagan Raya, ETD Unsyiah.




DOI: https://doi.org/10.35308/jopt.v5i2.1255

Refbacks

  • There are currently no refbacks.


Copyright (c) 2019 Jurnal Optimalisasi



JOPT: Jurnal Optimalisasi Indexing and Abstracting by: